Abstract:
This research aimed to exhibit the effects of variation of grain size, hardness and ultrasonic energy input for improving the
residual stress measurement by ultrasonic in low carbon steel. Low carbon steel (SS400) was used to vary its grain size and
hardness by fully annealing with 6 different temperature levels. The grain size and hardness of each specimen were analyzed
by the microscope and hardness testing machine. Then each specimen was applied static tension load below yield point. The
load was increased at 25 N/mm2
(MPa) in increment. Through transmission technique with probe 2 MHz and surface ultrasonic
wave were used. Ultrasonic energy input generated from Pulser-Receiver was changed its Pulser Voltage (PV) and Pulse
Repetition Frequency (PRF). Traveling time of ultrasonic surface wave was measured by using Pulser/Receiver and displayed
by an oscilloscope to calculate the ultrasonic velocity. The average of acoustoelastic coefficient was calculated based on the
correlation between ultrasonic velocity and tensile stress. The results showed that the speed of ultrasonic waves depended on
grain size and hardness of material. The ultrasonic energy input affected to the residual stress measurement. Finally, the
constant value for residual stress measurement was created to increase the accuracy of residual stress determination